Topology: |
V-LISN |
|
Frequency Range: |
9 kHz - 30 MHz |
|
Pre-filter choke: |
250 µH |
|
Impedance simulation: |
50 Ω || (50 µH + 5 Ω) |
|
Max. Current: |
2 x 16 A CEE 7/4 Type F (Schuko socket) and 4 x 16 A IEC 60309 3L+N+PE 16 A (CEKON-socket)
|
|
Max. Voltage: |
250 VAC 50/60 Hz 400 VDC |
|
Supply cable: |
Cable with CEKON plug |
|
Connector for EuT: |
CEE 7/4 Type F (Schuko socket)/ IEC 60309 3L+N+PE 16 A (CEKON-socket)
|
|
Connector for „artificial hand“: |
4 mm laboratory socket with screw terminal 6 mm, not removable |
|
Connector to EMI receiver: |
BNC socket 50 Ω |
|
|
|
|
Lenght: |
405 mm |
|
Width: |
448 mm |
|
Height: |
180 mm |
|
Weight: |
12.5 kg |
|
|
|
|
|
|
|
Standard: |
CISPR 16-1-2 |
Datasheet NSLK 8126
Options:
Opt. RC:
Option RC for LISN: Remote Control with built in power supply. LISN can be controlled by R&S or Schwarzbeck code, including remote control cable for your receiver type (Please specify your receiver type!). LISN can be selected from the R&S receiver menu or in the EMC32 software like an R&S LISN. No programming of the user interface necessary. Functions: path selection and PE grounded or via choke.
NSLK 8126 Opt. RC
|